ELECTRICS

ATPL Electrics - Complete Reference Guide

⚡ ATPL ELECTRICS

Complete Reference Guide for Aircraft Electrical Systems

⚡ Quick Reference - Critical Values

6.25×10¹⁸
Electrons in 1 Coulomb
0.707
RMS = Peak × 0.707
115V
AC Phase Voltage
200V
AC Line Voltage
400 Hz
Aircraft AC Frequency
28V DC
Standard DC Voltage
12-18 Ah
Typical Battery Capacity
80%
Min Battery Capacity

SECTION 1 Basic Direct Current Theory

Fundamental Charge Particles

  • Electron: Negative charge (−ve)
  • Proton: Positive charge (+ve)
  • Neutron: No charge (neutral)

Atomic Equilibrium

In a neutral atom, the number of electrons = protons. When this balance is disturbed through ionization, the atom acquires a net charge.

Valence Shell Concept

The valence shell is the outermost electron shell. Electrons in this shell are called valence electrons and determine electrical conductivity:

  • Few valence electrons → Conductor
  • ~4 valence electrons → Semiconductor
  • Many valence electrons → Insulator

Types of Drift

  • Random Drift: Natural random movement of electrons
  • Directed Drift: Organized electron flow when potential difference is applied

⚠️ Two Flow Conventions

  • Electron Flow: −ve to +ve (actual physical flow)
  • Conventional Flow: +ve to −ve (historical convention)

In aviation, we typically use conventional flow.

Definition of Current

Current = Charge / Time
I = Q / t

Where:

  • I = Current in Amperes (A)
  • Q = Charge in Coulombs (C)
  • t = Time in seconds (s)

The Coulomb

One Coulomb = 6.25 × 10¹⁸ electrons

This is the fundamental unit of electrical charge.

Ammeter Connection

An ammeter must be connected in SERIES with the circuit to measure current flow.

EMF & Voltage

Electromotive Force (EMF) or Potential Difference (PD) is the electrical "pressure" that drives current through a circuit.

  • Symbol: V or U
  • Unit: Volts (V)
  • Measured by: Voltmeter (connected in PARALLEL)

Key Characteristics

  • Potential is always present even if circuit is open
  • Analogy: Waterfall behind a dam - pressure exists even without flow
  • Voltmeter must have HIGH RESISTANCE to avoid affecting circuit

Resistance Calculation

Resistance = (Specific Resistance × Length) / Cross-Sectional Area
R = (ρ × L) / A

Where:

  • ρ (rho) = Specific resistance at 0°C
  • L = Length of conductor
  • A = Cross-sectional area

Conductance

Conductance is the reciprocal of resistance:

G = 1 / R

Unit: Siemens (S)

Temperature Coefficients

Positive Temperature Coefficient

Resistance INCREASES with temperature

Found in most conductors

Negative Temperature Coefficient

Resistance DECREASES with temperature

Found in insulators and semiconductors

⚡ Resistor Combinations

Configuration Total Resistance Formula
SERIES RT = R₁ + R₂ + R₃
PARALLEL 1/RT = 1/R₁ + 1/R₂ + 1/R₃

Important: Adding resistors in parallel DECREASES total resistance and INCREASES current (assuming constant V).

⚡ OHM'S LAW - FUNDAMENTAL

V = I × R

Where:

  • V = Voltage (Volts)
  • I = Current (Amperes)
  • R = Resistance (Ohms)

This is the most fundamental relationship in electrical circuits.

Kirchhoff's Laws

First Law (Current Law)

The sum of currents ENTERING a junction must equal the sum of currents EXITING.

Conservation of charge

Second Law (Voltage Law)

In any closed circuit, the sum of voltage drops equals the supply voltage.

Conservation of energy

⚡ Power Formulas (Watts)

P = V × I
P = I² × R
P = V² / R

Where:

  • P = Power in Watts (W)
  • V = Voltage (V)
  • I = Current (A)
  • R = Resistance (Ω)

Principle of Operation

A Wheatstone Bridge is used to measure unknown resistance with high precision.

Balanced Condition

When the bridge is balanced, the galvanometer (very sensitive ammeter) reads ZERO.

R₁ × R₃ = R₂ × RX

This allows calculation of unknown resistance RX.

Finding Voltage Drop

To find the voltage drop across a specific resistor in a series circuit:

V₁ = (R₁ / RT) × VT

Where:

  • V₁ = Voltage across resistor 1
  • R₁ = Value of resistor 1
  • RT = Total resistance
  • VT = Total voltage

SECTION 2 Aircraft Wiring & Protections

Dipole / Two-Wire System

Uses two separate conductors for current flow and return path.

Application: Mainly used on aircraft constructed from non-conductive/non-metallic materials (e.g., composite aircraft).

Unipole System (Single Pole / Earth Return)

The metallic airframe acts as the return path between load and power source.

Advantages:

  • ✓ Reduces wiring and saves space
  • ✓ Low resistance (due to large cross-section)
  • ✓ Saves weight
  • ✓ Easier to trace origin of wiring faults

Disadvantage:

  • ✗ Short circuits more likely

⚠️ Earth Polarity Systems

Earth is always defined as 0V reference.

Negative Earth System

Earth connected to −ve terminal of battery

+ve terminal reads: +12V

Potential Difference = 12V

Positive Earth System

Earth connected to +ve terminal of battery

−ve terminal reads: −12V

Potential Difference = 12V

Important: In both cases, the PD is still 12V (NOT +12V or −12V).

⚠️ SHORT CIRCUITS - CRITICAL HAZARD

Occurs when the load is bypassed, creating a direct path between supply and return.

Consequences:

  • 🔥 Extremely HIGH current flows due to negligible resistance
  • 🔥 Can damage circuit components
  • 🔥 Can burn cables
  • 🔥 FIRE HAZARD

OPEN CIRCUITS

Occurs when there is a break in a conductor.

Result: Load becomes inoperative (same as opening a switch).

Fuse Specifications

  • Rating: In Amperes (A)
  • Construction: Low melting point filament in glass or ceramic envelope
  • Location: As near to the supply as possible

⚠️ Spare Fuses Requirement

Aircraft must carry spare fuses:

10% with minimum of 3 for each rating

⚠️ In-Flight Fuse Replacement

Replace a fuse ONLY ONCE in flight.

If it blows again, there's a persistent fault - do not replace again.

Installation

The amp capacity of the device to be protected should be checked before installing a fuse.

Circuit Limiter Characteristics

  • Will allow for high transient loads
  • Only breaks with high CONTINUOUS overload
  • Application: Protect heavy-duty circuits (e.g., bus bar)
  • Construction: High melting point filament in ceramic housing

Circuit Breaker Advantages

  • ✓ Can be RESET - no spare fuses required
  • ✓ Can be used as switches to aid diagnosis
  • ✓ Can be used in both AC & DC circuits
  • ✓ Fitted in SERIES with protected circuit

⚠️ Circuit Breaker Operation

When popped (tripped), a WHITE BAND will show.

Protects system in event of:

  • Overload
  • Overheating

Thermal Circuit Breaker

Uses bi-metallic strip that bends when heated.

Response: Protects against PROLONGED overcurrent

Delayed response due to time taken to heat strip

Magnetic Circuit Breaker

Uses electromagnetic force to trip.

Response: FASTER than thermal type

Does not rely on heating

⚠️ CRITICAL: Circuit Breaker Reset Procedures

  • CB should ONLY be reset if necessary for safe flight and landing
  • Fault must be rectified before reset
  • Only ONE RESET should be attempted

Non-Trip Free CB

The CB can be held in against the fault.

⚠️ This can cause damage to the circuit.

Trip Free CB

Secondary contact prevents early reset.

✓ NOT possible to hold contacts closed while fault exists.

Safer design - prevents operator override

Definition

"A build-up of electrical charge on the surface of objects."

Occurs when electrons are transferred between materials - also known as the Triboelectric Effect.

⚠️ Conditions for Static Build-up

Most likely in:

  • Dry / low humidity air
  • Extreme turbulence

Causes of Static Electricity

  • 🔄 Friction (skin & propellers rubbing against air)
  • ⚡ Lightning strikes
  • ⚙️ Electrical circuits & equipment

🔥 Effects of Static Electricity - HAZARDS

  • ⚡ Materials attract/repel each other
  • 🔥 SPARKS and associated FIRE RISK
  • ⚠️ 'Pitting' of materials leading to corrosion
  • 📡 Interference with radio equipment
  • ✨ St Elmo's Fire

Purpose of Bonding

  • ⚡ Equalizing of static charges / potential
  • 🔌 Provide a single earth for unipole system
  • ⚡ Safe transmission of lightning discharges
  • 📡 Reduce radio interference (sign of poor bonding)
  • ⚠️ Prevention of electric shocks
  • 🔥 Prevention of static discharges (fire hazard)
  • ⚡ Provides safe distribution of electrical charges and currents

Bonding Definition & Method

Bonding is the connection of two or more metallic objects by means of a conductor.

  • Achieved using bonding strips
  • Creates a Faraday cage
  • Creates an electrical path of negligible resistance throughout the structure

Grounding

Will equalize the airframe to 0V and remove the static charge that has built up during flight.

Corona Discharge

If a static charge on the aircraft fails to dissipate, corona discharge occurs:

  • Occurs at minimum radii (sharp points)
  • Causes glow + interference

Static Discharge Wicks Function

Located on the trailing edges of wings and control surfaces.

Functions:

  • ✓ Safely dissipate static charges
  • ✓ Minimize radio interference
  • ✓ Limit risk of electrical charge transfer between aircraft and electrified clouds

Landing Protection

Used to equalize to earth potential upon landing:

  • Earthing strips
  • Semi-conductive tires

⚠️ Lightning Strike Effects

  • Some components may become MAGNETIZED if struck
  • Compass becomes INACCURATE
  • Some electrical systems may fail

Cable Screening

Enclosing of cables in a continuous metal sheath to reduce radio interference.

SECTION 3 Batteries

Electrochemical Process

  • Reduction: Loss of electrons at cathode (+)
  • Oxidation: Gain of electrons at anode (−)
  • Reduction/oxidation caused by electrolyte
  • Potential difference exists as electrolyte is a conductor

⚠️ Discharge Behavior

EMF reduces as deposits build up.

Tendency for voltage to decrease under load when almost fully discharged.

Recharging

Recharged with DC of slightly higher voltage than battery nominal voltage.

Primary Cell

NOT rechargeable

Duration: ~10 minutes

Use: Emergency lighting

Secondary Cell

Rechargeable

Duration: ~30 minutes

Use: Aircraft batteries

Lead-Acid Battery Specifications

  • Deposits: Lead Sulphate
  • Spillage neutralizer: Bicarbonate of Soda
  • Charging method: Constant Voltage Method
  • Nominal cell voltage: 2.2V

⚠️ Cold Temperature Effects

A fully charged lead-acid battery is LESS LIKELY to freeze in cold temperatures.

Discharged batteries are more susceptible to freezing.

Alkaline Cell Specifications

  • Deposits: Cadmium & Nickel Hydroxide
  • Spillage neutralizer: Boric Acid
  • Charging method: Pulse Charging (FASTER than Lead-Acid)
  • Nominal cell voltage: 1.2V

⚠️ THERMAL RUNAWAY RISK

Alkaline batteries are susceptible to thermal runaway during charging.

Cycle:

Temp ↑ → Internal Resistance ↓ → Current ↑ → Temp ↑

Indication: Significant increase in battery temperature

Why Alkaline Batteries are Preferred in Aviation

  • ✓ Lead-acid have insufficient capacity
  • ✓ Lead-acid are volume and weight inefficient
  • ✓ Alkaline has more stable voltage output before rapid discharge
  • ✓ Alkaline weighs less than lead-acid
  • ✓ Wider permissible temperature range
  • ✓ Good storage capability
  • ✓ Sturdiness owing to metal casing

⚠️ Alkaline Disadvantages

  • ✗ Suffer from memory effect
  • ✗ Risk of thermal runaway

Capacity Definition & Measurement

Battery capacity is a measure of the total energy it contains.

Capacity (Ah) = Current (A) × Time (h)
  • Unit: Ampere-hours (Ah)
  • Depends on: Size and number of plates

⚠️ MANDATORY CAPACITY CHECKS

  • Actual capacity checked every 3 MONTHS
  • Must be 80% or more of rated capacity
  • If below 80%, battery is unserviceable

Typical Aviation Capacity

Typical battery capacity in aviation: 12-18 Ah

⚠️ Hydrogen Gas Generation

Used to remove/contain volatile hydrogen gas given off during charging due to temperature increase.

Water lost by evaporation must be topped up from time to time with DISTILLED WATER.

Lead-Acid Venting

  • Non-Spill Vent: Prevents electrolyte spillage during maneuvers
  • Cell Cross-Flow System: Passes cabin pressurization air over top of cells
  • Sealed Batteries: For aerobatic/military aircraft

Alkaline Venting

  • Semi-Open: Uses Cross-Flow System
  • Sealed Batteries: For specific applications

⚡ Battery Connection Rules

Configuration Voltage Capacity
SERIES ADD voltages Capacity same as ONE cell
PARALLEL Voltage same as ONE cell ADD capacities

Charge State Determination

  • Ascertained by comparing on-load and off-load battery voltages
  • In lead-acid battery, can also measure Specific Gravity (SG) of electrolyte

⚠️ Temperature Impact

Cold temperatures REDUCE the capacity of the battery.

Mitigation:

  • Constant charge
  • Thermal blanket

⚠️ CRITICAL: Broken Cell Effect

If one of the cells within a lead-acid battery has a broken connection, the battery is rendered UNSERVICEABLE.

Reason: Since cells are connected in SERIES, one broken cell breaks the entire circuit.

BCU Functions

The Battery Control Unit isolates the battery from the bus when:

  • ✓ Battery charge has been completed
  • ✓ Battery overheat condition occurs
  • ✓ Internal short circuit occurs

⚡ Primary Function

One of the main functions of the battery in large transport aircraft is to be an EMERGENCY SOURCE OF ELECTRICAL POWER.

SECTION 4 Magnetism & Electromagnetism

Electromagnetic Field Formation

  • A static electron is surrounded by an electrostatic field
  • A moving electron (spinning around its axis) produces a magnetic field
  • The electrostatic field is at RIGHT ANGLES to the magnetic field
  • This combination forms an electromagnetic field

Natural Magnetism

Other than Earth, loadstone is the only natural magnet.

All other magnets are produced artificially.

Magnetic Domain Alignment

  • In an unmagnetized metal, domains are randomly arranged → overall field is ZERO
  • When subjected to a strong magnetic field, domains line up → metal becomes a magnet

⚡ Flux Line Properties

  • Originate from North Pole (NP) and go to South Pole (SP)
  • This property of direction = polarity
  • WITHIN the magnet: Flux lines run from SP to NP (completes the loop)
  • Flux lines NEVER CROSS each other
  • Flux density is GREATEST INSIDE the magnet

Division of Magnets

Each individual piece forms a complete magnet (with N and S poles), although strength is decreased.

Ferromagnetic Materials

The property of a material enabling it to become a magnet when placed in a magnetic field.

Examples: Iron, Cobalt, Nickel

Soft Iron (Temporary Magnet)

  • ✓ Easily magnetized
  • ✓ Easily loses magnetism

Hard Iron (Permanent Magnet)

  • Hard to magnetize
  • Retains magnetism very well

Saturation Point

When a magnet can no longer accept magnetism, it is said to be SATURATED.

⚠️ Remanent Flux

Once driven to saturation (max flux density), the magnetizing force can be removed but the material will retain most of its flux (remanent flux).

Coercive Force

A coercive force (reversing the magnetizing force) must be applied to remove the flux.

Flux density LAGS BEHIND the changing values of magnetizing forces.

⚡ Current-Induced Magnetic Field

When current flows through a conductor, a magnetic field is produced around the conductor.

Magnitude ∝ Current Flow

Right Hand Grasp Rule

  • Thumb: Direction of current flow
  • Fingers: Direction of magnetic field

Wire Loop & Coil

When a wire loop is created, there is greater flux density in the center of loop.

Multiple loops form a coil.

Coil Properties

  • Takes on same properties as a permanent magnet with polarity
  • Unlike a normal magnet, can be turned ON and OFF easily

Making Electromagnet Stronger

  • ✓ More current
  • ✓ More loops (turns)
  • ✓ Soft iron core

Determining Polarity of Coil

  • RH Fingers: Direction of current flow
  • RH Thumb: Direction of North Pole

Relay Definition

A relay is an electrically operated switch.

An electromagnet is used to operate a hinged switching mechanism.

Solenoid Characteristics

  • A relay that can handle HIGH POWER
  • Differs from relay by using a plunger-type switch
  • Contains a moving soft iron bar and mechanical linkage
  • Allows control switches to be smaller and situated remotely from switched element

SECTION 5 DC Generators

⚡ Fundamental Principle

When a conductor cuts the field lines of a magnetic field, an EMF (Lorentz force) is induced in the conductor.

Faraday's Law - Factors Affecting EMF

The amount of EMF induced depends on:

  • Strength of magnetic field (MOST IMPORTANT)
  • Angle at which conductor cuts the field
  • Length of conductor in field
  • Speed of conductor with respect to field

Fleming's Right Hand Rule

  • First Finger: Field direction
  • Center Finger: Current direction
  • Thumb: Motion direction

Used for GENERATORS

Generator Components

  • Stator: Casing that normally remains static and contains field windings
  • Rotor: Contains armature and commutator; normally rotates within stator

Operation Sequence

  1. Battery passes current through field winding, inducing magnetic field
  2. Rotor is turned by engine
  3. Current is induced within armature
  4. Part of induced EMF now provides current for field windings
  5. Battery no longer required

⚠️ Conditions Required to Start

  • Presence of a permanent field
  • Minimum rotation speed

Important Note

The same effect occurs if stator is rotated and rotor held constant. It is the relative movement that matters.

Commutator Function

  • The generator outputs AC naturally
  • A commutator is used to rectify to DC
  • Contains carbon brushes
  • Ensures only positive current flows to positive terminal and vice versa

Improved Output Stability

More armatures can be used to provide a more stable output voltage.

⚠️ Engine Protection

Weak point designed to SHEAR and protect the engine if the generator seizes.

Series Wound Generator

Field windings connected in SERIES with armature.

Problem: Not normally used as voltage is difficult to regulate.

  • As loads added in parallel, resistance drops
  • Current increases and feeds straight back to field windings
  • Voltage output increases (unstable)

Shunt Wound Generator

Field windings connected in PARALLEL with armature.

✓ Increased loads cause slight fall in voltage output but this is predictable.

Compound Wound

Some field winding in series and some in parallel.

Not widely used except on larger aircraft.

Voltage Regulation Function

As engine RPM increases, output voltage will vary unless corrected.

Voltmeter senses circuit (output) voltage and controls generator output by varying the field strength.

Carbon Pile

Uses carbon pile - a mechanical variable resistor.

  • Resistance DECREASES when compressed
  • Resistance INCREASES when expanded

⚠️ Regulation Process

When engine RPM increased:

  1. Higher DC voltage output from generator
  2. Solenoid receives more voltage
  3. Carbon pile extended
  4. Resistance increased → current to field windings reduced
  5. Generator output reduced

Connection Configuration

Carbon pile and field windings are connected in SERIES with each other but in a SHUNT WOUND arrangement.

DCO Functions

  • Commands the line contactor (relay-type switch) to join generator to bus bar once producing enough electricity
  • Protects generator from battery voltage when engine shut down
  • Isolates generator when reverse current of 20-30 amps sensed
  • Will allow 11.5V at GEN and 12V at battery

⚠️ Generator Warning Light

A generator warning light will illuminate when:

GEN V < BATT V and switch is open

⚠️ RCCB Protection

In the event of short circuit, protects:

  • Line Contactor (LC)
  • Differential Cut Out (DCO)
  • Generator (GEN)

Activates when reverse current of 300-500 amps sensed.

⚠️ RCCB Type & Reset

  • Electromagnetic type CB (faster reaction than thermal)
  • Can ONLY be manually reset once tripped

⚠️ Generator Overheat

  • GEN cooling fan exhaust > 160°C
  • Overheat lamp illuminates
  • GEN should be manually turned OFF and ON again after cooling

⚠️ Overvoltage Condition

Occurs when voltage regulator unserviceable.

Can be isolated:

  • Automatically with DCO
  • Manually with GEN switch

Zero Left Ammeter

Reads ONLY when generator is providing current.

Center Zero Ammeter

  • Reads −ve when battery providing
  • Reads +ve when generator providing
  • Shows battery charge/discharge rate

⚠️ High Charge Rate After Start

High charge rate after start is expected (battery recharging) but should return to normal within a short time.

Busbar Definition & Function

Busbars are low resistance conductors that serve as current distribution points.

They provide convenient means of connecting positive supplies to various loads.

  • Loads on busbar connected in PARALLEL
  • Can group loads according to importance
  • In event of generator failure, non-essential loads can be quickly turned off

⚡ Busbar Types

Busbar Type Loads
ESS (Essential) Flight Instruments, Compass, Radio, Cockpit Lighting
NON-ESS (Non-Essential) Galley services, etc.
HOT BAT Emergency Lights, Fire Extinguishers, Landing Gear
NO SWITCH - always connected
BAT BUSBAR Enough for initial check and start

Split Busbar

Each engine feeds independent busbars.

Parallel Busbar (Most Common)

Busbars share load from each generator.

✓ Provides MAXIMUM POWER

Load Sharing

Required to ensure same lifespan of each generator and provide greater redundancy.

Method: Equalizing coils installed to voltage regulators to adjust output by varying current in field coil.

Differential Relay

Ensures generator voltages are almost equal before they are paralleled.

⚠️ Hold-Off Relay

Short auxiliary pin in ground power socket operates a hold-off relay:

  • Disconnects GEN & BATT when ground power in use
  • Prevents thermal runaway from overcharging battery

Feeder Faults

On a DC circuit, results from a flux unbalance between the voltage coil and the series winding turn.

Voltage Regulator Load Response

If electrical load increased, VR will increase intensity of excitation current.

Generator Breaker

  • CLOSES when voltage of generator > battery voltage
  • OPENS when battery voltage > generator voltage

Load Shedding

Results in a current decrease.

Generator Cooling

Achieved using ram air.

SECTION 6 DC Motors

⚡ Fundamental Motor Principle

When a current-carrying conductor is placed in a magnetic field, the field around the conductor reacts with the magnetic field, causing the conductor to move.

Fleming's Left Hand Rule (Motors)

  • First Finger: Field direction
  • Center Finger: Current direction
  • Thumb: Motion direction

Used for MOTORS

Direction Reversal

Reversing the current causes the conductor to move in the opposite direction.

⚠️ Back EMF Generation

Induced motion causes a back EMF.

  • Direction determined using Fleming's Right Hand Rule (Generators)
  • More current through conductor → stronger back EMF

Natural Speed Regulation

DC motors are SELF-REGULATING:

  • On Load: Stabilizes at LOWER speed
  • Off Load: Stabilizes at HIGHER speed

⚠️ Series Motor

  • When off-loaded, RPM is VERY HIGH
  • Must be started on load
  • Ideal as starter motor due to high torque at low RPM

Shunt Motor

  • Fairly constant RPM across loads
  • Used for: Fuel pumps, fans, etc.

Compound Motor

Not normally used due to cost.

⚠️ Frictional Clutch Protection

Frictional clutch will SLIP when force from motor becomes too great.

Purpose: Protects the engine gearbox

Dual Function Unit

Since a motor is essentially a generator provided with current, they can be combined into one unit.

Battery Configuration During Start

Batteries in PARALLEL

  • 24V to ESS BUS
  • 24V to STARTER BUS

Batteries in SERIES

  • 24V to ESS BUS
  • 48V to STARTER BUS

⚠️ Series to Parallel Switching

Starter initially starts with 24V to reduce initial torque, thereby increasing its life.

Switching done by speed switch:

  • Connects in series when RPM between 10-60%

Control and Protection Unit

Located in PARALLEL with the generator.

Contains:

  • DCO (Differential Cut Out)
  • LC (Line Contactor)
  • RCCB (Reverse Current Circuit Breaker)
  • Voltage Regulator

Actuator Definition

High-speed, reversible, series-wound motors that convert high motor speed into high driving torque.

They are motors specifically designed for mechanical movement.

Reversibility Methods

Reversibility achieved by:

  • Reversing the current through armature or field coil
  • Reversing polarity of either stator or rotor
  • CANNOT do both at same time

Why Series-Wound?

Series-wound configuration to achieve HIGH TORQUE INITIALLY to overcome inertia.

⚠️ Friction Plates (Protection)

Friction plates (single/multi-plate) must be installed to prevent damage.

Rotary Actuator

Used to operate valves in:

  • Air conditioning system
  • Fuel system

Linear Actuator

Used to operate:

  • Flaps
  • Other linear movement systems

⚡ Limit Switches

Stop the motor when they read the desired setting.

  • Normally CLOSED to allow current flow to power motor
  • OPEN when actuator reaches limit of travel to stop motor

Electromagnetic Brakes

Prevent:

  • Over-travel
  • Undesired movement when motor switched off

SECTION 7 Single Engine Aircraft Electrical System

Purpose of Rectifier

Converts AC to DC.

Half Wave Rectifier

A diode is used which only allows current flow in one direction.

Problem: A pulse DC current is produced which is INEFFICIENT.

Full Wave Rectifier

4 diodes used in a diode bridge configuration.

Operation:

  • Phase 1: Current through diode A → load → diode C
  • Phase 2: AC changes direction; current through diode B → load (same direction) → diode D

⚠️ Output Smoothing

DC output varies between max voltage and 0V.

A capacitor is used to fill voltage gaps and give constant DC output.

Alternator Advantages

A more EFFICIENT way of generating electricity compared with DC generator.

⚡ Reversed Roles

Roles of rotor and stator are REVERSED:

  • Magnetic field rotates on ROTOR
  • Conductors (armature) are on STATOR

3 Phase Rectifier

Required to convert 3-phase AC to DC:

  • Consists of 6 diodes
  • Only 4 diodes in use at any one time
  • Capacitor used for output smoothing

Frequency Wild DC System

Alternator speed dictated by engine RPM, so frequency is NOT regulated at a constant value.

Voltage Regulation

Voltage regulator maintains output of 13.6V - 14.3V by altering current into rotor field windings.

Protection & Indicators

  • Overvoltage relay: Protects loads from overcurrents
  • Diode: Used instead of RCCB
  • Low Voltage Lamp: Flashes when output voltage drops below 13.6V
  • ALT Light: Illuminates when alternator offline

⚠️ Engine Protection

Rotor driven by drive belt. In event of alternator seizure, engine is protected (belt slips/breaks).

Zero-Left / Loadmeter

Measures output current from alternator.

Centre Reading Ammeter

  • Measures flow of current to/from battery
  • Shows battery charge/discharge rate

Full Picture Monitoring

Both types are sometimes fitted to provide full picture of system behavior.

SECTION 8 Inductance & Capacitance

What is Inductance?

When current flow is reversed through a conductor (as with AC), the flux lines change when current is reversed.

The effect: A back EMF is induced which OPPOSES the change in current flow.

Definition

Inductance is a measure of the ability for a device/circuit to produce a back EMF.

  • High Inductance = Greater back EMF
  • Unit: Henry (H)

Inductor Definition

A device designed to have a specific value of inductance.

Increasing Inductance

The inductance of an inductor can be increased by:

  • ✓ Increasing number of coil turns
  • ✓ Inserting soft iron core

⚡ Inductors in Series & Parallel

Configuration Total Inductance
SERIES LT = L₁ + L₂ + L₃
(Directly added)
PARALLEL 1/LT = 1/L₁ + 1/L₂ + 1/L₃
(Add reciprocals)

What is Capacitance?

The property of an electrical component which enables it to store energy in an electrostatic field.

C = Q / V

Where:

  • C = Capacitance in Farads (F)
  • Q = Charge in Coulombs (C)
  • V = Voltage in Volts (V)

Basic Construction

Two metal plates separated by a non-conductive material called a dielectric.

Factors Affecting Capacitance

C ∝ (k × A) / d

Capacitance depends on:

  • A: Area of plates
  • k: Type of dielectric
  • d: Distance between plates

Can be fixed or variable.

Charging Process

  1. Initially, both plates have same number of free electrons
  2. When supply connected, surplus of electrons occurs on one plate
  3. Deficiency occurs on other plate
  4. Potential difference equal but opposite to supply created across plates

Discharging Process

When removed from supply and connected across resistor, capacitor will discharge.

⚡ Capacitor Combinations

Configuration Total Capacitance Physical Effect
SERIES 1/CT = 1/C₁ + 1/C₂ + 1/C₃
(Add reciprocals)
Thickness decreased
→ Capacitance DECREASES
PARALLEL CT = C₁ + C₂ + C₃
(Directly added)
Area increased
→ Capacitance INCREASES

SECTION 9 Basic AC Theory

AC Advantages Over DC

  • ✓ Easy to TRANSFORM from one voltage to another
  • ✓ Easier to construct AC generators
  • ✓ Easy to rectify to DC
  • ✓ Information can be sent on AC

Key Terms

  • Instantaneous Voltage: Voltage at a specific instant in time
  • Peak Value: One positive and one negative peak value per cycle
  • Peak-to-Peak Value: Peak Value × 2

Average Value

The average of instantaneous values in a cycle:

Average Value = 0.637 × Peak Value

⚡ RMS - MOST IMPORTANT AC MEASUREMENT

In reality, it's useful to compare AC efficiency with DC supply.

Since AC follows sine pattern, electrons are 'lost' compared to DC.

RMS Value = 0.707 × Peak Value

RMS Definition

The DC voltage/current that produces an EQUIVALENT HEATING EFFECT.

Example:

  • 240V AC supply from mains has peak value of 339V
  • Provides same heating effect as 240V DC supply

⚠️ Important Note

RMS measure is USED when stating voltages and current of AC systems.

IN PHASE

If peaks and troughs of two waves at the same frequency COINCIDE, they are IN PHASE.

⚠️ OUT OF PHASE

When peaks and troughs do NOT coincide.

Example: If peak voltage occurs 90° before peak current:

  • Voltage LEADS current by 90°
  • OR Current LAGS voltage by 90°

Resistive Circuit Characteristics

  • Voltage and current are IN PHASE
  • Power is always positive
  • All power can be used to do useful work
  • TRUE POWER is produced

⚡ Capacitive Circuit Phase

Current LEADS voltage by 90 degrees.

⚠️ Power Characteristics

  • Voltage across capacitor always in constant opposition to supply voltage
  • Voltage is "pushed back"
  • Useful power CANCELLED OUT by reactive power
  • NO TRUE POWER AVAILABLE

Capacitive Reactance (XC)

The opposition to current generated is called capacitive reactance.

XC = 1 / (2πfC)

Where:

  • XC = Capacitive reactance (Ω)
  • f = Frequency (Hz)
  • C = Capacitance (F)

⚡ Inductive Circuit Phase

Voltage LEADS current by 90 degrees.

⚠️ Power Characteristics

  • Current is "pushed back"
  • Useful power CANCELLED OUT by reactive power
  • NO TRUE POWER AVAILABLE

Inductive Reactance (XL)

The opposition to current generated is called inductive reactance.

XL = 2πfL

Where:

  • XL = Inductive reactance (Ω)
  • f = Frequency (Hz)
  • L = Inductance (H)

⚡ CIVIL RULE

In reality, circuits contain all 3 types of resistance (R, XC, XL).

The CIVIL rule helps determine the net effect:

If XC > XL

Circuit is mainly CAPACITIVE

Current LEADS voltage

(CIV...)

If XL > XC

Circuit is mainly INDUCTIVE

Voltage LEADS current

(... VIL)

Resultant phase difference will be somewhere between 0 and 90 degrees.

Ideal Situation

Ideally, we want to achieve ZERO phase difference so all power is TRUE POWER that can do useful work.

⚡ Total Opposition in Circuit

Impedance is the total opposition present in a circuit.

It is the resultant vector of R, XC, and XL.

Z = √[R² + (XL − XC)²]

Unit: Ohms (Ω)

Definition

The frequency at which XC = XL

⚡ IDEAL SITUATION

At resonant frequency:

  • Total impedance is JUST THE RESISTANCE
  • Since purely resistive circuit is IN PHASE
  • Current flow is MAXIMUM
  • All power is TRUE POWER

This is the IDEAL situation.

True / Effective / Real Power (W)

Power consumed by resistive components within circuit.

Unit: Watts (W)

Reactive Power (VAR)

Power consumed by reactive components (capacitors + inductors).

Unit: Volt-Ampere Reactive (VAR)

Apparent Power (VA)

Total power required to meet circuit demand (true power) and overcome reactance (reactive power).

Unit: Volt-Ampere (VA)

⚡ Power Factor

Power Factor = True Power / Apparent Power

Typically 70-90% in aircraft electrical systems.

SECTION 10 Transformers

Three Primary Functions

  • ✓ Convert one voltage to another voltage
  • ✓ Isolate sections of circuits (primary from secondary)
  • ✓ Allow passage of AC whilst BLOCKING DC

Operation Principle

  1. AC voltage applied to primary winding
  2. Flux changes produced
  3. Flux induces EMF within secondary winding

Voltage Transformation

  • Voltage INCREASES if more turns on secondary coil
  • Voltage DECREASES if fewer turns on secondary coil

⚡ Turns Ratio Formula

Turns Ratio = NS / NP = VS / VP

Where:

  • NS = Number of turns on secondary
  • NP = Number of turns on primary
  • VS = Secondary voltage
  • VP = Primary voltage

Power Conservation

Assuming 100% efficient transformer, power remains constant.

Given P = I × V:

  • Step-up: Voltage increases → Current DECREASES
  • Step-down: Voltage decreases → Current INCREASES

High Efficiency

Transformers are very efficient.

Typically 80-95% efficient.

⚠️ No Isolation

  • NO ISOLATION between primary and secondary
  • Uses continuous winding
  • ✓ Lighter and cheaper than isolation type
  • ✗ Does NOT isolate

Variable Autotransformer

Can be used to control lighting intensity.

Non-Invasive Current Measurement

  • Feeder cable passed through soft iron ring with windings
  • Alternating magnetic field induces EMF in windings
  • Ammeter connected to windings measures current
  • Use: Measure output of AC generator

Combined Unit

Contains transformer AND rectifier for use when DC output required.

Secondary winding connected to 3-phase full wave bridge diode rectifier.

Rotary Inverter

  • DC powers motor which drives AC generator on common shaft
  • Around 50% efficient (energy lost to mechanical energy)

Static / Transistorized Inverter

  • ✓ More reliable and requires less servicing
  • ✓ Much more efficient (~75%) - no mechanical loss
  • ✗ Power limited compared to rotary inverter

SECTION 11 3-Phase Machines

Why 3-Phase AC?

  • ✓ Higher efficiency possible in AC generation
  • ✓ Fewer conductors required
  • ✓ Same source can be used for single/three phase AC supplies
  • ✓ 3-phase motors have better characteristics than single-phase ones

Phase Relationship

As rotor rotates, peak voltages are induced 120° apart.

⚡ Line vs Phase Voltage

  • Line Voltage: PD between a line and neutral point
  • Phase Voltage: PD between two phases
Line Voltage = √3 × Phase Voltage

Star Connection Characteristics

Line Voltage = √3 × Phase Voltage
Line Current = Phase Current

There is only one path for current to flow through between phases.

Delta Connection Characteristics

Line Voltage = Phase Voltage
Line Current = √3 × Phase Current

There are two paths for current to flow.

Star Method

  • Uses 4 conductors:
    • 1 for each phase
    • 1 for neutral point

Delta Method

  • Uses 3 conductors
  • NO neutral point

Efficiency Comparison

Both produce same power although delta connection is lighter with only 3 conductors.

⚠️ Aviation Requirement

STAR method REQUIRED in aviation since there's no earth connection available.

The neutral is needed to absorb excessive current.

⚡ STANDARD AC VALUES

Parameter Value
Frequency 400 Hz
Phase Voltage 115 V
Line Voltage 200 V

Control Methods

  • Voltage: Controlled by adjusting field excitation via voltage regulator
  • Frequency: Adjusted via rotational speed of rotor and number of magnetic field poles
f = (N × P) / 60

Where:

  • f = Frequency (Hz)
  • N = RPM
  • P = Number of pole pairs

Advantage of Multiple Poles

Increasing number of poles allows same frequency to be generated at LOWER RPM.

⚠️ Brush Type Generators

Example: Salient Pole Generator

  • Electromagnets on rotor excited with DC current via carbon brushes and slip rings
  • ✗ Intermittent contacts produce SPARKS
  • ✗ Sparks increase in intensity with altitude (lower air density = less insulation)

✓ Brushless Type Generator

Components:

  1. CSDU: Rotates shaft giving constant output frequency
  2. PMG (Permanent Magnet Generator): Induces AC voltage in pilot exciter
  3. Voltage Regulator: Rectifies to DC and feeds to main exciter
  4. Main Exciter: Produces 3-phase AC, rectified to DC, passed to main generator
  5. Main Generator: Produces final 3-phase AC output (115V/200V)

⚡ Why Constant Speed?

Constant speed and hence constant frequency is important to achieve correct and constant resonant frequency within circuit.

CSDU Operation

  • Governor senses CSDU output RPM
  • Adjusts pressure within hydraulic pump
  • Alters RPM of motor
  • Ensures constant RPM obtained (usually 8,000 RPM)

⚠️ Maintenance & Operation

  • Hydraulic fluid sight glass to be checked on pre-flight
  • CSDU can be DISCONNECTED in event of abnormal functioning
  • Once disconnected, can ONLY be reset on ground

VSCF Generator

Variable Speed Constant Frequency

  • ✓ Recent development
  • ✓ No mechanical gears/hydraulics
  • ✗ Cannot match power output of IDG

IDG (Integrated Drive Generator)

CSDU + Generator in same unit

Most common on modern aircraft.

Basic AC Motor Operation

  • Rotating magnetic field set up within stator field coils
  • Soft iron bar mounted on rotor shaft follows magnetic field
  • Shaft rotates
  • Slight lag exists due to mechanical loading → shaft lags magnetic field (synchronous speed)
Slip Speed = Synchronous Speed − Rotor Speed

Slip Speed Control

Increasing voltage will strengthen magnetic field and reduce slip speed.

Induction / Asynchronous Motor

By mounting conductors on a cage, EMF induced within conductors as magnetic field from stators rotates.

This creates magnetic field within conductors on cage.

Interaction of fields causes cage to rotate.

⚠️ Loss of Phase

  • Motor will continue to run at reduced torque
  • May overheat as remaining phases carry greater current
  • If not already running, motor CANNOT be started (fuses/CBs will blow)

Two Phase Induction Motor

  • One phase = reference phase
  • Other phase = control phase
  • Changing phase changes direction of magnetic field
  • Rotor re-aligns itself with field
  • Use: Autopilot servo motors

Split Phase Induction Motor

  • Behaves like two-phase induction motor
  • One winding = capacitive
  • Other winding = resistive
  • Use: Drive actuators

Single Phase Induction Motor

  • Rotates continuously in one direction
  • Changes direction when field reversed
  • Generally NOT used on aircraft

Synchronous Motor

  • Used when constant speed required at high RPMs
  • Ideal for: Gyroscopes
  • Rotor carries field windings
  • Creates magnetic field that aligns with stator field
  • Initial period where asynchronous as inertia overcome

SECTION 12 AC Supply & Distribution

Frequency Wild

Used in light aircraft for heaters, etc.

Constant Frequency

  • Split Busbar
  • Parallel Busbar

⚠️ Important Principle

Parallel loads are ONLY allowed with DC and must be kept separate in AC.

Normal Operation (Both GENs Running)

Only ONE BTB (Bus Tie Breaker) will be open to allow powering of AC ESS BUS.

⚠️ Generator Failure

In event a GEN fails:

  • BOTH BTBs CLOSED
  • Allows one GEN to feed AC BUS 1, AC ESS BUS, & AC BUS 2

Key Components

  • GCU (Generator Control Unit): Controls opening/closing of GCB
  • GCB (Generator Circuit Breaker): Switch (not CB) connecting generator to system
  • DPC (Differential Protection Circuit): Monitors generator output vs return current to detect leaks; opens GCB via GCU if fault detected

⚡ Conditions for Paralleling

AC generators must have following conditions in common BEFORE they can be paralleled:

  • ✓ Voltage
  • ✓ Frequency
  • ✓ Phase Difference
  • ✓ Phase Order

✓ Advantages

  • ✓ Redundancy
  • ✓ Load Sharing
  • ✓ Prolonged Generator Life

✗ Disadvantages

  • ✗ Fault Propagation
  • ✗ Does NOT meet independent system requirements

⚠️ MANDATORY Conditions Before Connecting

Before connecting external power:

  • ✓ Correct Voltage
  • ✓ Correct Frequency
  • ✓ Correct Phase Order
  • ✓ Dead AC Busbar (no other sources providing power to it)

Load Sharing Methods

  • Real Load Sharing: Adjusting magnetic trim in the CSDUs
  • Reactive Load Sharing: Adjusting excitation of generator fields

⚠️ General Troubleshooting

  1. Separate generators by opening BTBs
  2. They may settle down once separated
  3. If one generator is persistent problem, trip GB and GFR

⚡ EASA TROUBLESHOOTING ANSWERS

Fault Action
Persistent Under-Excitation Trip Exciter Breaker & Generator Breaker
Persistent Over-Excitation Trip Exciter Breaker & Generator Breaker
Persistent Over-Voltage Trip Exciter Breaker & Generator Breaker
"AC Generator Fault" Trip Exciter Breaker & Generator Breaker
Underspeed Fault Open GB ONLY to allow stabilization
Persistent Phase Imbalance Open BTB to allow independent operation

Fire Handle Pull Effect

Pulling fire handle opens:

  • Exciter Control Relay
  • Generator Breaker
  • BTB operation depends on system