⚡ ATPL ELECTRICS
Complete Reference Guide for Aircraft Electrical Systems
⚡ Quick Reference - Critical Values
SECTION 1 Basic Direct Current Theory
Fundamental Charge Particles
- Electron: Negative charge (−ve)
- Proton: Positive charge (+ve)
- Neutron: No charge (neutral)
Atomic Equilibrium
In a neutral atom, the number of electrons = protons. When this balance is disturbed through ionization, the atom acquires a net charge.
Valence Shell Concept
The valence shell is the outermost electron shell. Electrons in this shell are called valence electrons and determine electrical conductivity:
- Few valence electrons → Conductor
- ~4 valence electrons → Semiconductor
- Many valence electrons → Insulator
Types of Drift
- Random Drift: Natural random movement of electrons
- Directed Drift: Organized electron flow when potential difference is applied
⚠️ Two Flow Conventions
- Electron Flow: −ve to +ve (actual physical flow)
- Conventional Flow: +ve to −ve (historical convention)
In aviation, we typically use conventional flow.
Definition of Current
Where:
- I = Current in Amperes (A)
- Q = Charge in Coulombs (C)
- t = Time in seconds (s)
The Coulomb
One Coulomb = 6.25 × 10¹⁸ electrons
This is the fundamental unit of electrical charge.
Ammeter Connection
An ammeter must be connected in SERIES with the circuit to measure current flow.
EMF & Voltage
Electromotive Force (EMF) or Potential Difference (PD) is the electrical "pressure" that drives current through a circuit.
- Symbol: V or U
- Unit: Volts (V)
- Measured by: Voltmeter (connected in PARALLEL)
Key Characteristics
- Potential is always present even if circuit is open
- Analogy: Waterfall behind a dam - pressure exists even without flow
- Voltmeter must have HIGH RESISTANCE to avoid affecting circuit
Resistance Calculation
Where:
- ρ (rho) = Specific resistance at 0°C
- L = Length of conductor
- A = Cross-sectional area
Conductance
Conductance is the reciprocal of resistance:
Unit: Siemens (S)
Temperature Coefficients
Positive Temperature Coefficient
Resistance INCREASES with temperature
Found in most conductors
Negative Temperature Coefficient
Resistance DECREASES with temperature
Found in insulators and semiconductors
⚡ Resistor Combinations
| Configuration | Total Resistance Formula |
|---|---|
| SERIES | RT = R₁ + R₂ + R₃ |
| PARALLEL | 1/RT = 1/R₁ + 1/R₂ + 1/R₃ |
Important: Adding resistors in parallel DECREASES total resistance and INCREASES current (assuming constant V).
⚡ OHM'S LAW - FUNDAMENTAL
Where:
- V = Voltage (Volts)
- I = Current (Amperes)
- R = Resistance (Ohms)
This is the most fundamental relationship in electrical circuits.
Kirchhoff's Laws
First Law (Current Law)
The sum of currents ENTERING a junction must equal the sum of currents EXITING.
Conservation of charge
Second Law (Voltage Law)
In any closed circuit, the sum of voltage drops equals the supply voltage.
Conservation of energy
⚡ Power Formulas (Watts)
Where:
- P = Power in Watts (W)
- V = Voltage (V)
- I = Current (A)
- R = Resistance (Ω)
Principle of Operation
A Wheatstone Bridge is used to measure unknown resistance with high precision.
Balanced Condition
When the bridge is balanced, the galvanometer (very sensitive ammeter) reads ZERO.
This allows calculation of unknown resistance RX.
Finding Voltage Drop
To find the voltage drop across a specific resistor in a series circuit:
Where:
- V₁ = Voltage across resistor 1
- R₁ = Value of resistor 1
- RT = Total resistance
- VT = Total voltage
SECTION 2 Aircraft Wiring & Protections
Dipole / Two-Wire System
Uses two separate conductors for current flow and return path.
Application: Mainly used on aircraft constructed from non-conductive/non-metallic materials (e.g., composite aircraft).
Unipole System (Single Pole / Earth Return)
The metallic airframe acts as the return path between load and power source.
Advantages:
- ✓ Reduces wiring and saves space
- ✓ Low resistance (due to large cross-section)
- ✓ Saves weight
- ✓ Easier to trace origin of wiring faults
Disadvantage:
- ✗ Short circuits more likely
⚠️ Earth Polarity Systems
Earth is always defined as 0V reference.
Negative Earth System
Earth connected to −ve terminal of battery
+ve terminal reads: +12V
Potential Difference = 12V
Positive Earth System
Earth connected to +ve terminal of battery
−ve terminal reads: −12V
Potential Difference = 12V
Important: In both cases, the PD is still 12V (NOT +12V or −12V).
⚠️ SHORT CIRCUITS - CRITICAL HAZARD
Occurs when the load is bypassed, creating a direct path between supply and return.
Consequences:
- 🔥 Extremely HIGH current flows due to negligible resistance
- 🔥 Can damage circuit components
- 🔥 Can burn cables
- 🔥 FIRE HAZARD
OPEN CIRCUITS
Occurs when there is a break in a conductor.
Result: Load becomes inoperative (same as opening a switch).
Fuse Specifications
- Rating: In Amperes (A)
- Construction: Low melting point filament in glass or ceramic envelope
- Location: As near to the supply as possible
⚠️ Spare Fuses Requirement
Aircraft must carry spare fuses:
10% with minimum of 3 for each rating
⚠️ In-Flight Fuse Replacement
Replace a fuse ONLY ONCE in flight.
If it blows again, there's a persistent fault - do not replace again.
Installation
The amp capacity of the device to be protected should be checked before installing a fuse.
Circuit Limiter Characteristics
- Will allow for high transient loads
- Only breaks with high CONTINUOUS overload
- Application: Protect heavy-duty circuits (e.g., bus bar)
- Construction: High melting point filament in ceramic housing
Circuit Breaker Advantages
- ✓ Can be RESET - no spare fuses required
- ✓ Can be used as switches to aid diagnosis
- ✓ Can be used in both AC & DC circuits
- ✓ Fitted in SERIES with protected circuit
⚠️ Circuit Breaker Operation
When popped (tripped), a WHITE BAND will show.
Protects system in event of:
- Overload
- Overheating
Thermal Circuit Breaker
Uses bi-metallic strip that bends when heated.
Response: Protects against PROLONGED overcurrent
Delayed response due to time taken to heat strip
Magnetic Circuit Breaker
Uses electromagnetic force to trip.
Response: FASTER than thermal type
Does not rely on heating
⚠️ CRITICAL: Circuit Breaker Reset Procedures
- CB should ONLY be reset if necessary for safe flight and landing
- Fault must be rectified before reset
- Only ONE RESET should be attempted
Non-Trip Free CB
The CB can be held in against the fault.
⚠️ This can cause damage to the circuit.
Trip Free CB
Secondary contact prevents early reset.
✓ NOT possible to hold contacts closed while fault exists.
Safer design - prevents operator override
Definition
"A build-up of electrical charge on the surface of objects."
Occurs when electrons are transferred between materials - also known as the Triboelectric Effect.
⚠️ Conditions for Static Build-up
Most likely in:
- Dry / low humidity air
- Extreme turbulence
Causes of Static Electricity
- 🔄 Friction (skin & propellers rubbing against air)
- ⚡ Lightning strikes
- ⚙️ Electrical circuits & equipment
🔥 Effects of Static Electricity - HAZARDS
- ⚡ Materials attract/repel each other
- 🔥 SPARKS and associated FIRE RISK
- ⚠️ 'Pitting' of materials leading to corrosion
- 📡 Interference with radio equipment
- ✨ St Elmo's Fire
Purpose of Bonding
- ⚡ Equalizing of static charges / potential
- 🔌 Provide a single earth for unipole system
- ⚡ Safe transmission of lightning discharges
- 📡 Reduce radio interference (sign of poor bonding)
- ⚠️ Prevention of electric shocks
- 🔥 Prevention of static discharges (fire hazard)
- ⚡ Provides safe distribution of electrical charges and currents
Bonding Definition & Method
Bonding is the connection of two or more metallic objects by means of a conductor.
- Achieved using bonding strips
- Creates a Faraday cage
- Creates an electrical path of negligible resistance throughout the structure
Grounding
Will equalize the airframe to 0V and remove the static charge that has built up during flight.
Corona Discharge
If a static charge on the aircraft fails to dissipate, corona discharge occurs:
- Occurs at minimum radii (sharp points)
- Causes glow + interference
Static Discharge Wicks Function
Located on the trailing edges of wings and control surfaces.
Functions:
- ✓ Safely dissipate static charges
- ✓ Minimize radio interference
- ✓ Limit risk of electrical charge transfer between aircraft and electrified clouds
Landing Protection
Used to equalize to earth potential upon landing:
- Earthing strips
- Semi-conductive tires
⚠️ Lightning Strike Effects
- Some components may become MAGNETIZED if struck
- Compass becomes INACCURATE
- Some electrical systems may fail
Cable Screening
Enclosing of cables in a continuous metal sheath to reduce radio interference.
SECTION 3 Batteries
Electrochemical Process
- Reduction: Loss of electrons at cathode (+)
- Oxidation: Gain of electrons at anode (−)
- Reduction/oxidation caused by electrolyte
- Potential difference exists as electrolyte is a conductor
⚠️ Discharge Behavior
EMF reduces as deposits build up.
Tendency for voltage to decrease under load when almost fully discharged.
Recharging
Recharged with DC of slightly higher voltage than battery nominal voltage.
Primary Cell
NOT rechargeable
Duration: ~10 minutes
Use: Emergency lighting
Secondary Cell
Rechargeable
Duration: ~30 minutes
Use: Aircraft batteries
Lead-Acid Battery Specifications
- Deposits: Lead Sulphate
- Spillage neutralizer: Bicarbonate of Soda
- Charging method: Constant Voltage Method
- Nominal cell voltage: 2.2V
⚠️ Cold Temperature Effects
A fully charged lead-acid battery is LESS LIKELY to freeze in cold temperatures.
Discharged batteries are more susceptible to freezing.
Alkaline Cell Specifications
- Deposits: Cadmium & Nickel Hydroxide
- Spillage neutralizer: Boric Acid
- Charging method: Pulse Charging (FASTER than Lead-Acid)
- Nominal cell voltage: 1.2V
⚠️ THERMAL RUNAWAY RISK
Alkaline batteries are susceptible to thermal runaway during charging.
Cycle:
Temp ↑ → Internal Resistance ↓ → Current ↑ → Temp ↑
Indication: Significant increase in battery temperature
Why Alkaline Batteries are Preferred in Aviation
- ✓ Lead-acid have insufficient capacity
- ✓ Lead-acid are volume and weight inefficient
- ✓ Alkaline has more stable voltage output before rapid discharge
- ✓ Alkaline weighs less than lead-acid
- ✓ Wider permissible temperature range
- ✓ Good storage capability
- ✓ Sturdiness owing to metal casing
⚠️ Alkaline Disadvantages
- ✗ Suffer from memory effect
- ✗ Risk of thermal runaway
Capacity Definition & Measurement
Battery capacity is a measure of the total energy it contains.
- Unit: Ampere-hours (Ah)
- Depends on: Size and number of plates
⚠️ MANDATORY CAPACITY CHECKS
- Actual capacity checked every 3 MONTHS
- Must be 80% or more of rated capacity
- If below 80%, battery is unserviceable
Typical Aviation Capacity
Typical battery capacity in aviation: 12-18 Ah
⚠️ Hydrogen Gas Generation
Used to remove/contain volatile hydrogen gas given off during charging due to temperature increase.
Water lost by evaporation must be topped up from time to time with DISTILLED WATER.
Lead-Acid Venting
- Non-Spill Vent: Prevents electrolyte spillage during maneuvers
- Cell Cross-Flow System: Passes cabin pressurization air over top of cells
- Sealed Batteries: For aerobatic/military aircraft
Alkaline Venting
- Semi-Open: Uses Cross-Flow System
- Sealed Batteries: For specific applications
⚡ Battery Connection Rules
| Configuration | Voltage | Capacity |
|---|---|---|
| SERIES | ADD voltages | Capacity same as ONE cell |
| PARALLEL | Voltage same as ONE cell | ADD capacities |
Charge State Determination
- Ascertained by comparing on-load and off-load battery voltages
- In lead-acid battery, can also measure Specific Gravity (SG) of electrolyte
⚠️ Temperature Impact
Cold temperatures REDUCE the capacity of the battery.
Mitigation:
- Constant charge
- Thermal blanket
⚠️ CRITICAL: Broken Cell Effect
If one of the cells within a lead-acid battery has a broken connection, the battery is rendered UNSERVICEABLE.
Reason: Since cells are connected in SERIES, one broken cell breaks the entire circuit.
BCU Functions
The Battery Control Unit isolates the battery from the bus when:
- ✓ Battery charge has been completed
- ✓ Battery overheat condition occurs
- ✓ Internal short circuit occurs
⚡ Primary Function
One of the main functions of the battery in large transport aircraft is to be an EMERGENCY SOURCE OF ELECTRICAL POWER.
SECTION 4 Magnetism & Electromagnetism
Electromagnetic Field Formation
- A static electron is surrounded by an electrostatic field
- A moving electron (spinning around its axis) produces a magnetic field
- The electrostatic field is at RIGHT ANGLES to the magnetic field
- This combination forms an electromagnetic field
Natural Magnetism
Other than Earth, loadstone is the only natural magnet.
All other magnets are produced artificially.
Magnetic Domain Alignment
- In an unmagnetized metal, domains are randomly arranged → overall field is ZERO
- When subjected to a strong magnetic field, domains line up → metal becomes a magnet
⚡ Flux Line Properties
- Originate from North Pole (NP) and go to South Pole (SP)
- This property of direction = polarity
- WITHIN the magnet: Flux lines run from SP to NP (completes the loop)
- Flux lines NEVER CROSS each other
- Flux density is GREATEST INSIDE the magnet
Division of Magnets
Each individual piece forms a complete magnet (with N and S poles), although strength is decreased.
Ferromagnetic Materials
The property of a material enabling it to become a magnet when placed in a magnetic field.
Examples: Iron, Cobalt, Nickel
Soft Iron (Temporary Magnet)
- ✓ Easily magnetized
- ✓ Easily loses magnetism
Hard Iron (Permanent Magnet)
- Hard to magnetize
- Retains magnetism very well
Saturation Point
When a magnet can no longer accept magnetism, it is said to be SATURATED.
⚠️ Remanent Flux
Once driven to saturation (max flux density), the magnetizing force can be removed but the material will retain most of its flux (remanent flux).
Coercive Force
A coercive force (reversing the magnetizing force) must be applied to remove the flux.
Flux density LAGS BEHIND the changing values of magnetizing forces.
⚡ Current-Induced Magnetic Field
When current flows through a conductor, a magnetic field is produced around the conductor.
Magnitude ∝ Current Flow
Right Hand Grasp Rule
- Thumb: Direction of current flow
- Fingers: Direction of magnetic field
Wire Loop & Coil
When a wire loop is created, there is greater flux density in the center of loop.
Multiple loops form a coil.
Coil Properties
- Takes on same properties as a permanent magnet with polarity
- Unlike a normal magnet, can be turned ON and OFF easily
Making Electromagnet Stronger
- ✓ More current
- ✓ More loops (turns)
- ✓ Soft iron core
Determining Polarity of Coil
- RH Fingers: Direction of current flow
- RH Thumb: Direction of North Pole
Relay Definition
A relay is an electrically operated switch.
An electromagnet is used to operate a hinged switching mechanism.
Solenoid Characteristics
- A relay that can handle HIGH POWER
- Differs from relay by using a plunger-type switch
- Contains a moving soft iron bar and mechanical linkage
- Allows control switches to be smaller and situated remotely from switched element
SECTION 5 DC Generators
⚡ Fundamental Principle
When a conductor cuts the field lines of a magnetic field, an EMF (Lorentz force) is induced in the conductor.
Faraday's Law - Factors Affecting EMF
The amount of EMF induced depends on:
- Strength of magnetic field (MOST IMPORTANT)
- Angle at which conductor cuts the field
- Length of conductor in field
- Speed of conductor with respect to field
Fleming's Right Hand Rule
- First Finger: Field direction
- Center Finger: Current direction
- Thumb: Motion direction
Used for GENERATORS
Generator Components
- Stator: Casing that normally remains static and contains field windings
- Rotor: Contains armature and commutator; normally rotates within stator
Operation Sequence
- Battery passes current through field winding, inducing magnetic field
- Rotor is turned by engine
- Current is induced within armature
- Part of induced EMF now provides current for field windings
- Battery no longer required
⚠️ Conditions Required to Start
- Presence of a permanent field
- Minimum rotation speed
Important Note
The same effect occurs if stator is rotated and rotor held constant. It is the relative movement that matters.
Commutator Function
- The generator outputs AC naturally
- A commutator is used to rectify to DC
- Contains carbon brushes
- Ensures only positive current flows to positive terminal and vice versa
Improved Output Stability
More armatures can be used to provide a more stable output voltage.
⚠️ Engine Protection
Weak point designed to SHEAR and protect the engine if the generator seizes.
Series Wound Generator
Field windings connected in SERIES with armature.
Problem: Not normally used as voltage is difficult to regulate.
- As loads added in parallel, resistance drops
- Current increases and feeds straight back to field windings
- Voltage output increases (unstable)
Shunt Wound Generator
Field windings connected in PARALLEL with armature.
✓ Increased loads cause slight fall in voltage output but this is predictable.
Compound Wound
Some field winding in series and some in parallel.
Not widely used except on larger aircraft.
Voltage Regulation Function
As engine RPM increases, output voltage will vary unless corrected.
Voltmeter senses circuit (output) voltage and controls generator output by varying the field strength.
Carbon Pile
Uses carbon pile - a mechanical variable resistor.
- Resistance DECREASES when compressed
- Resistance INCREASES when expanded
⚠️ Regulation Process
When engine RPM increased:
- Higher DC voltage output from generator
- Solenoid receives more voltage
- Carbon pile extended
- Resistance increased → current to field windings reduced
- Generator output reduced
Connection Configuration
Carbon pile and field windings are connected in SERIES with each other but in a SHUNT WOUND arrangement.
DCO Functions
- Commands the line contactor (relay-type switch) to join generator to bus bar once producing enough electricity
- Protects generator from battery voltage when engine shut down
- Isolates generator when reverse current of 20-30 amps sensed
- Will allow 11.5V at GEN and 12V at battery
⚠️ Generator Warning Light
A generator warning light will illuminate when:
GEN V < BATT V and switch is open
⚠️ RCCB Protection
In the event of short circuit, protects:
- Line Contactor (LC)
- Differential Cut Out (DCO)
- Generator (GEN)
Activates when reverse current of 300-500 amps sensed.
⚠️ RCCB Type & Reset
- Electromagnetic type CB (faster reaction than thermal)
- Can ONLY be manually reset once tripped
⚠️ Generator Overheat
- GEN cooling fan exhaust > 160°C
- Overheat lamp illuminates
- GEN should be manually turned OFF and ON again after cooling
⚠️ Overvoltage Condition
Occurs when voltage regulator unserviceable.
Can be isolated:
- Automatically with DCO
- Manually with GEN switch
Zero Left Ammeter
Reads ONLY when generator is providing current.
Center Zero Ammeter
- Reads −ve when battery providing
- Reads +ve when generator providing
- Shows battery charge/discharge rate
⚠️ High Charge Rate After Start
High charge rate after start is expected (battery recharging) but should return to normal within a short time.
Busbar Definition & Function
Busbars are low resistance conductors that serve as current distribution points.
They provide convenient means of connecting positive supplies to various loads.
- Loads on busbar connected in PARALLEL
- Can group loads according to importance
- In event of generator failure, non-essential loads can be quickly turned off
⚡ Busbar Types
| Busbar Type | Loads |
|---|---|
| ESS (Essential) | Flight Instruments, Compass, Radio, Cockpit Lighting |
| NON-ESS (Non-Essential) | Galley services, etc. |
| HOT BAT | Emergency Lights, Fire Extinguishers, Landing Gear NO SWITCH - always connected |
| BAT BUSBAR | Enough for initial check and start |
Split Busbar
Each engine feeds independent busbars.
Parallel Busbar (Most Common)
Busbars share load from each generator.
✓ Provides MAXIMUM POWER
Load Sharing
Required to ensure same lifespan of each generator and provide greater redundancy.
Method: Equalizing coils installed to voltage regulators to adjust output by varying current in field coil.
Differential Relay
Ensures generator voltages are almost equal before they are paralleled.
⚠️ Hold-Off Relay
Short auxiliary pin in ground power socket operates a hold-off relay:
- Disconnects GEN & BATT when ground power in use
- Prevents thermal runaway from overcharging battery
Feeder Faults
On a DC circuit, results from a flux unbalance between the voltage coil and the series winding turn.
Voltage Regulator Load Response
If electrical load increased, VR will increase intensity of excitation current.
Generator Breaker
- CLOSES when voltage of generator > battery voltage
- OPENS when battery voltage > generator voltage
Load Shedding
Results in a current decrease.
Generator Cooling
Achieved using ram air.
SECTION 6 DC Motors
⚡ Fundamental Motor Principle
When a current-carrying conductor is placed in a magnetic field, the field around the conductor reacts with the magnetic field, causing the conductor to move.
Fleming's Left Hand Rule (Motors)
- First Finger: Field direction
- Center Finger: Current direction
- Thumb: Motion direction
Used for MOTORS
Direction Reversal
Reversing the current causes the conductor to move in the opposite direction.
⚠️ Back EMF Generation
Induced motion causes a back EMF.
- Direction determined using Fleming's Right Hand Rule (Generators)
- More current through conductor → stronger back EMF
Natural Speed Regulation
DC motors are SELF-REGULATING:
- On Load: Stabilizes at LOWER speed
- Off Load: Stabilizes at HIGHER speed
⚠️ Series Motor
- When off-loaded, RPM is VERY HIGH
- Must be started on load
- Ideal as starter motor due to high torque at low RPM
Shunt Motor
- Fairly constant RPM across loads
- Used for: Fuel pumps, fans, etc.
Compound Motor
Not normally used due to cost.
⚠️ Frictional Clutch Protection
Frictional clutch will SLIP when force from motor becomes too great.
Purpose: Protects the engine gearbox
Dual Function Unit
Since a motor is essentially a generator provided with current, they can be combined into one unit.
Battery Configuration During Start
Batteries in PARALLEL
- 24V to ESS BUS
- 24V to STARTER BUS
Batteries in SERIES
- 24V to ESS BUS
- 48V to STARTER BUS
⚠️ Series to Parallel Switching
Starter initially starts with 24V to reduce initial torque, thereby increasing its life.
Switching done by speed switch:
- Connects in series when RPM between 10-60%
Control and Protection Unit
Located in PARALLEL with the generator.
Contains:
- DCO (Differential Cut Out)
- LC (Line Contactor)
- RCCB (Reverse Current Circuit Breaker)
- Voltage Regulator
Actuator Definition
High-speed, reversible, series-wound motors that convert high motor speed into high driving torque.
They are motors specifically designed for mechanical movement.
Reversibility Methods
Reversibility achieved by:
- Reversing the current through armature or field coil
- Reversing polarity of either stator or rotor
- CANNOT do both at same time
Why Series-Wound?
Series-wound configuration to achieve HIGH TORQUE INITIALLY to overcome inertia.
⚠️ Friction Plates (Protection)
Friction plates (single/multi-plate) must be installed to prevent damage.
Rotary Actuator
Used to operate valves in:
- Air conditioning system
- Fuel system
Linear Actuator
Used to operate:
- Flaps
- Other linear movement systems
⚡ Limit Switches
Stop the motor when they read the desired setting.
- Normally CLOSED to allow current flow to power motor
- OPEN when actuator reaches limit of travel to stop motor
Electromagnetic Brakes
Prevent:
- Over-travel
- Undesired movement when motor switched off
SECTION 7 Single Engine Aircraft Electrical System
Purpose of Rectifier
Converts AC to DC.
Half Wave Rectifier
A diode is used which only allows current flow in one direction.
Problem: A pulse DC current is produced which is INEFFICIENT.
Full Wave Rectifier
4 diodes used in a diode bridge configuration.
Operation:
- Phase 1: Current through diode A → load → diode C
- Phase 2: AC changes direction; current through diode B → load (same direction) → diode D
⚠️ Output Smoothing
DC output varies between max voltage and 0V.
A capacitor is used to fill voltage gaps and give constant DC output.
Alternator Advantages
A more EFFICIENT way of generating electricity compared with DC generator.
⚡ Reversed Roles
Roles of rotor and stator are REVERSED:
- Magnetic field rotates on ROTOR
- Conductors (armature) are on STATOR
3 Phase Rectifier
Required to convert 3-phase AC to DC:
- Consists of 6 diodes
- Only 4 diodes in use at any one time
- Capacitor used for output smoothing
Frequency Wild DC System
Alternator speed dictated by engine RPM, so frequency is NOT regulated at a constant value.
Voltage Regulation
Voltage regulator maintains output of 13.6V - 14.3V by altering current into rotor field windings.
Protection & Indicators
- Overvoltage relay: Protects loads from overcurrents
- Diode: Used instead of RCCB
- Low Voltage Lamp: Flashes when output voltage drops below 13.6V
- ALT Light: Illuminates when alternator offline
⚠️ Engine Protection
Rotor driven by drive belt. In event of alternator seizure, engine is protected (belt slips/breaks).
Zero-Left / Loadmeter
Measures output current from alternator.
Centre Reading Ammeter
- Measures flow of current to/from battery
- Shows battery charge/discharge rate
Full Picture Monitoring
Both types are sometimes fitted to provide full picture of system behavior.
SECTION 8 Inductance & Capacitance
What is Inductance?
When current flow is reversed through a conductor (as with AC), the flux lines change when current is reversed.
The effect: A back EMF is induced which OPPOSES the change in current flow.
Definition
Inductance is a measure of the ability for a device/circuit to produce a back EMF.
- High Inductance = Greater back EMF
- Unit: Henry (H)
Inductor Definition
A device designed to have a specific value of inductance.
Increasing Inductance
The inductance of an inductor can be increased by:
- ✓ Increasing number of coil turns
- ✓ Inserting soft iron core
⚡ Inductors in Series & Parallel
| Configuration | Total Inductance |
|---|---|
| SERIES | LT = L₁ + L₂ + L₃ (Directly added) |
| PARALLEL | 1/LT = 1/L₁ + 1/L₂ + 1/L₃ (Add reciprocals) |
What is Capacitance?
The property of an electrical component which enables it to store energy in an electrostatic field.
Where:
- C = Capacitance in Farads (F)
- Q = Charge in Coulombs (C)
- V = Voltage in Volts (V)
Basic Construction
Two metal plates separated by a non-conductive material called a dielectric.
Factors Affecting Capacitance
Capacitance depends on:
- A: Area of plates
- k: Type of dielectric
- d: Distance between plates
Can be fixed or variable.
Charging Process
- Initially, both plates have same number of free electrons
- When supply connected, surplus of electrons occurs on one plate
- Deficiency occurs on other plate
- Potential difference equal but opposite to supply created across plates
Discharging Process
When removed from supply and connected across resistor, capacitor will discharge.
⚡ Capacitor Combinations
| Configuration | Total Capacitance | Physical Effect |
|---|---|---|
| SERIES | 1/CT = 1/C₁ + 1/C₂ + 1/C₃ (Add reciprocals) |
Thickness decreased → Capacitance DECREASES |
| PARALLEL | CT = C₁ + C₂ + C₃ (Directly added) |
Area increased → Capacitance INCREASES |
SECTION 9 Basic AC Theory
AC Advantages Over DC
- ✓ Easy to TRANSFORM from one voltage to another
- ✓ Easier to construct AC generators
- ✓ Easy to rectify to DC
- ✓ Information can be sent on AC
Key Terms
- Instantaneous Voltage: Voltage at a specific instant in time
- Peak Value: One positive and one negative peak value per cycle
- Peak-to-Peak Value: Peak Value × 2
Average Value
The average of instantaneous values in a cycle:
⚡ RMS - MOST IMPORTANT AC MEASUREMENT
In reality, it's useful to compare AC efficiency with DC supply.
Since AC follows sine pattern, electrons are 'lost' compared to DC.
RMS Definition
The DC voltage/current that produces an EQUIVALENT HEATING EFFECT.
Example:
- 240V AC supply from mains has peak value of 339V
- Provides same heating effect as 240V DC supply
⚠️ Important Note
RMS measure is USED when stating voltages and current of AC systems.
IN PHASE
If peaks and troughs of two waves at the same frequency COINCIDE, they are IN PHASE.
⚠️ OUT OF PHASE
When peaks and troughs do NOT coincide.
Example: If peak voltage occurs 90° before peak current:
- Voltage LEADS current by 90°
- OR Current LAGS voltage by 90°
Resistive Circuit Characteristics
- Voltage and current are IN PHASE
- Power is always positive
- All power can be used to do useful work
- TRUE POWER is produced
⚡ Capacitive Circuit Phase
Current LEADS voltage by 90 degrees.
⚠️ Power Characteristics
- Voltage across capacitor always in constant opposition to supply voltage
- Voltage is "pushed back"
- Useful power CANCELLED OUT by reactive power
- NO TRUE POWER AVAILABLE
Capacitive Reactance (XC)
The opposition to current generated is called capacitive reactance.
Where:
- XC = Capacitive reactance (Ω)
- f = Frequency (Hz)
- C = Capacitance (F)
⚡ Inductive Circuit Phase
Voltage LEADS current by 90 degrees.
⚠️ Power Characteristics
- Current is "pushed back"
- Useful power CANCELLED OUT by reactive power
- NO TRUE POWER AVAILABLE
Inductive Reactance (XL)
The opposition to current generated is called inductive reactance.
Where:
- XL = Inductive reactance (Ω)
- f = Frequency (Hz)
- L = Inductance (H)
⚡ CIVIL RULE
In reality, circuits contain all 3 types of resistance (R, XC, XL).
The CIVIL rule helps determine the net effect:
If XC > XL
Circuit is mainly CAPACITIVE
Current LEADS voltage
(CIV...)
If XL > XC
Circuit is mainly INDUCTIVE
Voltage LEADS current
(... VIL)
Resultant phase difference will be somewhere between 0 and 90 degrees.
Ideal Situation
Ideally, we want to achieve ZERO phase difference so all power is TRUE POWER that can do useful work.
⚡ Total Opposition in Circuit
Impedance is the total opposition present in a circuit.
It is the resultant vector of R, XC, and XL.
Unit: Ohms (Ω)
Definition
The frequency at which XC = XL
⚡ IDEAL SITUATION
At resonant frequency:
- Total impedance is JUST THE RESISTANCE
- Since purely resistive circuit is IN PHASE
- Current flow is MAXIMUM
- All power is TRUE POWER
This is the IDEAL situation.
True / Effective / Real Power (W)
Power consumed by resistive components within circuit.
Unit: Watts (W)
Reactive Power (VAR)
Power consumed by reactive components (capacitors + inductors).
Unit: Volt-Ampere Reactive (VAR)
Apparent Power (VA)
Total power required to meet circuit demand (true power) and overcome reactance (reactive power).
Unit: Volt-Ampere (VA)
⚡ Power Factor
Typically 70-90% in aircraft electrical systems.
SECTION 10 Transformers
Three Primary Functions
- ✓ Convert one voltage to another voltage
- ✓ Isolate sections of circuits (primary from secondary)
- ✓ Allow passage of AC whilst BLOCKING DC
Operation Principle
- AC voltage applied to primary winding
- Flux changes produced
- Flux induces EMF within secondary winding
Voltage Transformation
- Voltage INCREASES if more turns on secondary coil
- Voltage DECREASES if fewer turns on secondary coil
⚡ Turns Ratio Formula
Where:
- NS = Number of turns on secondary
- NP = Number of turns on primary
- VS = Secondary voltage
- VP = Primary voltage
Power Conservation
Assuming 100% efficient transformer, power remains constant.
Given P = I × V:
- Step-up: Voltage increases → Current DECREASES
- Step-down: Voltage decreases → Current INCREASES
High Efficiency
Transformers are very efficient.
Typically 80-95% efficient.
⚠️ No Isolation
- NO ISOLATION between primary and secondary
- Uses continuous winding
- ✓ Lighter and cheaper than isolation type
- ✗ Does NOT isolate
Variable Autotransformer
Can be used to control lighting intensity.
Non-Invasive Current Measurement
- Feeder cable passed through soft iron ring with windings
- Alternating magnetic field induces EMF in windings
- Ammeter connected to windings measures current
- Use: Measure output of AC generator
Combined Unit
Contains transformer AND rectifier for use when DC output required.
Secondary winding connected to 3-phase full wave bridge diode rectifier.
Rotary Inverter
- DC powers motor which drives AC generator on common shaft
- Around 50% efficient (energy lost to mechanical energy)
Static / Transistorized Inverter
- ✓ More reliable and requires less servicing
- ✓ Much more efficient (~75%) - no mechanical loss
- ✗ Power limited compared to rotary inverter
SECTION 11 3-Phase Machines
Why 3-Phase AC?
- ✓ Higher efficiency possible in AC generation
- ✓ Fewer conductors required
- ✓ Same source can be used for single/three phase AC supplies
- ✓ 3-phase motors have better characteristics than single-phase ones
Phase Relationship
As rotor rotates, peak voltages are induced 120° apart.
⚡ Line vs Phase Voltage
- Line Voltage: PD between a line and neutral point
- Phase Voltage: PD between two phases
Star Connection Characteristics
There is only one path for current to flow through between phases.
Delta Connection Characteristics
There are two paths for current to flow.
Star Method
- Uses 4 conductors:
- 1 for each phase
- 1 for neutral point
Delta Method
- Uses 3 conductors
- NO neutral point
Efficiency Comparison
Both produce same power although delta connection is lighter with only 3 conductors.
⚠️ Aviation Requirement
STAR method REQUIRED in aviation since there's no earth connection available.
The neutral is needed to absorb excessive current.
⚡ STANDARD AC VALUES
| Parameter | Value |
|---|---|
| Frequency | 400 Hz |
| Phase Voltage | 115 V |
| Line Voltage | 200 V |
Control Methods
- Voltage: Controlled by adjusting field excitation via voltage regulator
- Frequency: Adjusted via rotational speed of rotor and number of magnetic field poles
Where:
- f = Frequency (Hz)
- N = RPM
- P = Number of pole pairs
Advantage of Multiple Poles
Increasing number of poles allows same frequency to be generated at LOWER RPM.
⚠️ Brush Type Generators
Example: Salient Pole Generator
- Electromagnets on rotor excited with DC current via carbon brushes and slip rings
- ✗ Intermittent contacts produce SPARKS
- ✗ Sparks increase in intensity with altitude (lower air density = less insulation)
✓ Brushless Type Generator
Components:
- CSDU: Rotates shaft giving constant output frequency
- PMG (Permanent Magnet Generator): Induces AC voltage in pilot exciter
- Voltage Regulator: Rectifies to DC and feeds to main exciter
- Main Exciter: Produces 3-phase AC, rectified to DC, passed to main generator
- Main Generator: Produces final 3-phase AC output (115V/200V)
⚡ Why Constant Speed?
Constant speed and hence constant frequency is important to achieve correct and constant resonant frequency within circuit.
CSDU Operation
- Governor senses CSDU output RPM
- Adjusts pressure within hydraulic pump
- Alters RPM of motor
- Ensures constant RPM obtained (usually 8,000 RPM)
⚠️ Maintenance & Operation
- Hydraulic fluid sight glass to be checked on pre-flight
- CSDU can be DISCONNECTED in event of abnormal functioning
- Once disconnected, can ONLY be reset on ground
VSCF Generator
Variable Speed Constant Frequency
- ✓ Recent development
- ✓ No mechanical gears/hydraulics
- ✗ Cannot match power output of IDG
IDG (Integrated Drive Generator)
CSDU + Generator in same unit
Most common on modern aircraft.
Basic AC Motor Operation
- Rotating magnetic field set up within stator field coils
- Soft iron bar mounted on rotor shaft follows magnetic field
- Shaft rotates
- Slight lag exists due to mechanical loading → shaft lags magnetic field (synchronous speed)
Slip Speed Control
Increasing voltage will strengthen magnetic field and reduce slip speed.
Induction / Asynchronous Motor
By mounting conductors on a cage, EMF induced within conductors as magnetic field from stators rotates.
This creates magnetic field within conductors on cage.
Interaction of fields causes cage to rotate.
⚠️ Loss of Phase
- Motor will continue to run at reduced torque
- May overheat as remaining phases carry greater current
- If not already running, motor CANNOT be started (fuses/CBs will blow)
Two Phase Induction Motor
- One phase = reference phase
- Other phase = control phase
- Changing phase changes direction of magnetic field
- Rotor re-aligns itself with field
- Use: Autopilot servo motors
Split Phase Induction Motor
- Behaves like two-phase induction motor
- One winding = capacitive
- Other winding = resistive
- Use: Drive actuators
Single Phase Induction Motor
- Rotates continuously in one direction
- Changes direction when field reversed
- Generally NOT used on aircraft
Synchronous Motor
- Used when constant speed required at high RPMs
- Ideal for: Gyroscopes
- Rotor carries field windings
- Creates magnetic field that aligns with stator field
- Initial period where asynchronous as inertia overcome
SECTION 12 AC Supply & Distribution
Frequency Wild
Used in light aircraft for heaters, etc.
Constant Frequency
- Split Busbar
- Parallel Busbar
⚠️ Important Principle
Parallel loads are ONLY allowed with DC and must be kept separate in AC.
Normal Operation (Both GENs Running)
Only ONE BTB (Bus Tie Breaker) will be open to allow powering of AC ESS BUS.
⚠️ Generator Failure
In event a GEN fails:
- BOTH BTBs CLOSED
- Allows one GEN to feed AC BUS 1, AC ESS BUS, & AC BUS 2
Key Components
- GCU (Generator Control Unit): Controls opening/closing of GCB
- GCB (Generator Circuit Breaker): Switch (not CB) connecting generator to system
- DPC (Differential Protection Circuit): Monitors generator output vs return current to detect leaks; opens GCB via GCU if fault detected
⚡ Conditions for Paralleling
AC generators must have following conditions in common BEFORE they can be paralleled:
- ✓ Voltage
- ✓ Frequency
- ✓ Phase Difference
- ✓ Phase Order
✓ Advantages
- ✓ Redundancy
- ✓ Load Sharing
- ✓ Prolonged Generator Life
✗ Disadvantages
- ✗ Fault Propagation
- ✗ Does NOT meet independent system requirements
⚠️ MANDATORY Conditions Before Connecting
Before connecting external power:
- ✓ Correct Voltage
- ✓ Correct Frequency
- ✓ Correct Phase Order
- ✓ Dead AC Busbar (no other sources providing power to it)
Load Sharing Methods
- Real Load Sharing: Adjusting magnetic trim in the CSDUs
- Reactive Load Sharing: Adjusting excitation of generator fields
⚠️ General Troubleshooting
- Separate generators by opening BTBs
- They may settle down once separated
- If one generator is persistent problem, trip GB and GFR
⚡ EASA TROUBLESHOOTING ANSWERS
| Fault | Action |
|---|---|
| Persistent Under-Excitation | Trip Exciter Breaker & Generator Breaker |
| Persistent Over-Excitation | Trip Exciter Breaker & Generator Breaker |
| Persistent Over-Voltage | Trip Exciter Breaker & Generator Breaker |
| "AC Generator Fault" | Trip Exciter Breaker & Generator Breaker |
| Underspeed Fault | Open GB ONLY to allow stabilization |
| Persistent Phase Imbalance | Open BTB to allow independent operation |
Fire Handle Pull Effect
Pulling fire handle opens:
- Exciter Control Relay
- Generator Breaker
- BTB operation depends on system